2015年5月21日星期四

MKS-05P (TERRA-P)Personal Radiation Alarm Detector

Email Me
Chinacoal08

 Applicable occasions 

1. for civil construction evaluation of radioactive detection
2. personal dose monitoring alarm
3. industrial X-ray, gamma nondestructive flaw detection, radiation detection
4. radiology site radiation detection
5. cobalt source, electron accelerator irradiation
6. radioactive radiation detection laboratory radiation detection
7. nuclear facilities in the surrounding environment radiation detection 
8. soil surface contamination
9. radiation detection 
10. ore, building materials, radioactive pollution of agricultural products


Functional features

1.three separate measurement channels rotate in the same LCD screen display
2.built-in gamma, beta sensitive GM counters
3.automatically adjust the measurement time interval and measurement range
4.sound indicator to measure each of the gamma and beta radiation event particles
5.dose rate sound alarm limit can be set
6.digital display, four battery indicator.
7.two AAA batteries
8.shockproof housing, compact design

 Specifications:


1.Gamma radiation dose equivalent:0.01μSv-999.9mSv
2.Beta-particles surface radiation density:10-100 000;
3.Gamma radiation:0.05~3.0; ±25%MeV
4.Beta radiation:0.5~3.0;MeV
5.Temperature range: -10~+50°C
6.Size:120x52x26(mm)
7.Weight:0.2kg

Name
Unit of measurement
Standardized values according to theTD
Measurement range of photon-ionizing radiation EDR
mSv/h
0.1-999.9
Main relative permissible error limits of gamma radiation EDR measurement with 0.95possibility
%
+/-(25+2/D),D- is a numerical value of EDR measurement in mSv/h
Measurement range of gamma radiation ED
mSv
0.001-99.99
Main relative permissible error limits of gamma radiation ED measurement with 0.95%possibility
%
+/-25
Energy range of registered gamma radiation
MeV
0.05-3.00
Energy response of the dosimeter readings at gamma radiation EDR and ED measurement in the energy range from0.05 to1.25MeV
%
+/-25
Beta-particles flux density range with possible evalution of surface contamination by beta radio nuclides
Part./(cm2-min)
10-10.5
Registered beta-particles energies range
MeV
0.5-3.0
Time of continuous operation of the dosimeter from batteries(“Energizer”AAAx2of1280mA-h capacity)at natural background radiation,not less than
hrs
6000
Dimensions of the dosimeter,not more than
mm
55x26x120
Weight of the dosimeter,not more than
kg
0.2

没有评论:

发表评论