2015年7月2日星期四

NT6101 х-ray,gamma-ray radiation meter

Chinacoal08
Keywords: radiation meter,x-ray radition meter,gamm
  NT6101 x,gamma-ray radiation meter is specially designed to measure x-ray,gamma-ray radiation dosesor rate in all kinds of radioactive working areas.In comparison with similar meter in china ,this meter has a wider measuring range of dose rate. It has been widely used in hygiene department, environmental protection, metallurgy, petroleum, chemical industry, radioactive laboratories, commodity inspection and etc.

Feature

High sensitivity, wide measuring range, good energy response
High-speed low power consumption microprocessor
Digital and gauge double display
Chinese interface display
LCD digital display
800 group data can be saved
Dose rate and total doses can be measured
Alarm function (alarm function /choke/Detector failure)
Battery Indicator
Solid stainless steel shell

Technical data

Detectorφ30×25mmNaI
Sensibility1µSv/h≥350CPS
Energy threshold value35Kev
Measuring range:
Dose rate0.01500.00µSv/h
Accumulative dose:0.00µSv99999µSv
Energy range40Kev3Mev
Energy response≤±30%relative to137Cs
Relative error≤±10%
Measurement time1~120 adjustable
Alarm threshold0.252.5102060µSv/h
Display
Dose rate µSv/hµGy/hµR/h(selectable)
Accumulative doseµSv
Counting rate: CPS
Power source1#battery(Two batteries)
Power≤120mWnot contains backlighting power consumption
Weight:1.80Kg(contain battery)
Size 42×23×15(cm)


Technical data

Detector
φ30×25mmNaI
Sensibility
1µSv/h≥350CPS
Energy threshold value
35Kev
Measuring range:
Dose rate
0.01500.00µSv/h
Accumulative dose
0.00µSv99999µSv
Energy range
40Kev3Mev
Energy response
Less than or equal ±30%relative to137Cs
Relative error
Less than or equal ±10%
Measurement time
1~120 adjustable
Alarm threshold
0.252.5102060µSv/h
Display
Dose rate
µSv/hµGy/hµR/h(selectable)
Accumulative dose
µSv
Counting rate
CPS
Power source
1#battery(Two batteries)
Power
Less than or equal 120mWnot contains backlighting power consumption
Weight:1.80Kg(contain battery)
Size
42×23×15(cm)


NT6102 X-γ dosimeter-radiometer

Email Me
Chinacoal08

Purpose of use

Measurement of personal gamma and X-ray radiation equivalent dose rate(EDR)
Measurement of personal gamma and X-ray radiation equivalent dose(ED)
Alarm of exceeded programmed threshold levels

Application

Nuclear facilities around environmental radiation detection
The soil surface radiation pollution detection
Agricultural radiation pollution detection
Ore, building materials radioactive detection
Personal dose monitoring alarm
Industrial X, gamma NDT radiation detection
Radiation medical treatment place radiation detection
Cobalt source, electronic accelerator irradiation place radiation detection
Radioactive radiation laboratory detection

Specification

1. Types of measured Ray: X, γ and hard-β rays 
2. Measurement range:
Radiation equivalent dose rate(EDR):  0.01 µSv/h - 10000µSv/h
Radiation equivalent dose(ED): 
0.00 µSv - 9999Sv
3. Energy ranges of measurement: 
40KeV - 3.0MeV
4. Relative errors of energy dependence(137Cs): ≤±25% 
5. Basic relative errors::
 ≤±15%
6. Adjustable range of alarm threshold level relative to radiation dose rate: adjustable within the range 
7. Adjust able range of alarm threshold level relative to radiation dose: adjustable within the full range 
8. Response time of alarm: ≤5seconds
9. Display unit: 
EDR :(µSv/hmSv/hSv/h )
Count Rate:cpm
    ED:(µSvmSVSv)    
10. Power: one AAA battery 
11. Dimension: 105*55*26 (mm)
12. Weight: 80g (excluding battery)

Specification


Types of measured Ray
X, γ and hard-β rays 
Measurement range
Radiation equivalent dose rate(EDR)
0.01 µSv/h - 10000µSv/h
Radiation equivalent dose(ED)
0.00 µSv - 9999Sv
Energy ranges of measurement
40KeV - 3.0MeV
Relative errors of energy dependence(137Cs)
less than or equal±25% 
Basic relative errors
less than or equal ±15%
Adjustable range of alarm threshold level relative to radiation dose rate
adjustable within the range 
Adjust able range of alarm threshold level relative to radiation dose
adjustable within the full range 
Response time of alarm
Less tan or equal 5seconds
Display unit
EDR
(µSv/hmSv/hSv/h )
Count Rate
cpm
ED
(µSvmSVSv)  
Power
one AAA battery 
Dimension
105*55*26 (mm)
Weight
80g (excluding battery)

NT6103A radiation place monitor

Email Me
Chinacoal08

Product Introduction

Type NT6103A radiation place monitor is a type of economy is multi-purpose ray detecting instrument. Instruments built a radiation detector, high sensitivity adopted high-speed microprocessors for data processing, LED display is clearly visible, with super threshold sound and light alarm function.
Instrument can be used fixed in radioactive workplace, can also according to the need to move into a temporary surveillance area. Instrument USES switch power supply, can also be equipped with battery power supply, instrument can be used as portable X-ray detector.
It is environmental laboratory, irradiation chamber, nuclear medicine and molecular biology, radiochemistry and nuclear materials storage areas such as gamma and X-ray radiation dose rate test of the ideal instrument. NT6103A model for external detector, detector and host range up to 1000 meters.


Functional features
1.efficient GM tube detector
2. indicates a radioactive intensity of sound frequency
3. dose rate exceeds the threshold alarm function
4. ultra low power design
5.leds is highlighted
6. units show mu Sv/h, mR/h
7.exceeds the threshold alarm
8.alarm threshold can be set manually
9. jam alarm
10. detector failure indication
11. external sound and light alarm device
12. wall-mounted installation


Technical indicators
1.measuring range: 0.01 ~ 5000 uSv/h, 0.01 ~ 500 Mr/h
2. agent sensors: thin wall type of GM counter
3.energy range: 40 kev ~ 3 mev
4. acuity: p 3000 CPM/mR/h
5. relative error: 15% or less
6. power supply: DC 7 v ~ 24 v (standard 12 v switching power supply)
7. temperature range: - 10 ℃ to 50 ℃
8. humidity range: relative humidity of 95% or less (40 ℃)
9.host size weight: 0.5 kg; 160 * 110 * 35 mm
The configuration list
10. NT6103 type configuration: instruments, sound and light alarm, switch power, certification, warranty CARDS, manuals
11. NT6103A type configuration: host, detector, sound and light alarm, 10 meters connecting cable, switch power, certification, warranty CARDS, manuals

NT6103-J type stationary multi-channel radiation monitor

Email Me
Product Introduction
Chinacoal08
NT6103 - J type stationary multi-channel radiation monitor is a practical multi-channel radiation detection equipment. 
Data processing instrument adopts high speed microprocessors, highlight LED display with large size, has a super threshold sound and light alarm function. With a signal input and output function, can be connected to the interlock. Instrument can be used fixed in radioactive workplace, can also according to the need to move into a temporary surveillance area. Instrument USES switch power supply, can also be equipped with battery power supply, instrument can be used as portable X-ray detector. 
It is environmental laboratory, irradiation chamber, nuclear medicine and molecular biology, radiochemistry and nuclear materials storage areas such as gamma and X-ray radiation dose rate test of the ideal instrument.

Functional features
1.can connect one to four road detector, detector with display.
2.dose rate exceeds the threshold alarm function, and also optional alarm detector
3.LED the highlighted measurements and working condition
4. automatic switching range and display unit
5.alarm threshold can be set manually
6. detector failure indication
7.host built-in light alarm function, and can be an external high decibels sound and light alarm
8. can be wall-mounted or desktop installation
9.two input signals
10. two output signals
11.two way alarm output signal
12.detector and host communications furthest distance of up to 1000 meters
13. NT6103 - J host built-in efficient GM tube detector

Technical indicators

1. measuring range: 0.01 ~ 5000 uSv/h
2. agent sensors: thin wall type of GM counter
3. energy range: 40 kev ~ 3 mev
4. acuity: p 3000 CPM/mR/h
5. relative error: 15% or less
6.power supply: DC 7 v ~ 24 v (standard 12 v switching power supply)
7.temperature range: - 10 ℃ to 50 ℃
8. humidity range: relative humidity of 95% or less (40 ℃)
9. host size weight: 0.5 kg; 160 * 85 * 35 mm
10. detector size weight: 0.3 kg (100 * 70 * 27 mm

The configuration list

1.NT6103 - J host, 12 v power supply, external sound and light alarm, connecting cable (with 10 meters)
2. probe (quantity according to customer requirements)
3.instruction manual, warranty card, certificate of approval